Fm measurement, Level measurement – Kathrein MSK 25 User Manual

Page 42

Advertising
background image

FM measurement

42

Level Measurement

After you have set a frequency, the level is automatically measured and
displayed in dBµV. The input level can be measured in the range of
30 dBµV to 120 dBµV.

LC display:

• Frequency: 104.8 MHz
• Mode: FM
• Level measured: 86.5 dBµV

Level Overflow and Level Underflow

The LC display indicates underflow at a level of < 30 dBµV.

LC display:

• Frequency: 104.8 MHz
• Mode: FM
• Level: underflow

The LC display indicates overflow at a level of > 120 dBµV.

LC display:

• Frequency: 104.8 MHz
• Mode: TV
• Level: overflow

Fr:104.80MHz FM
LEV: 86.5dBuV A │

FR:104.80MHz FM
LEV: ___._dBuV A │

FR:104,80MHz FM
LEV:¯¯¯.¯dBuV A │