Tv measurement – Kathrein MSK 25 User Manual

Page 39

Advertising
background image

TV measurement

39

Press [3] while the sound carrier is displayed

Note

The sound carrier frequency is not adjustable but changed over
according to the standard which has been set.

The sound carrier level is only displayed when key [2] or [3] is pressed.

NICAM Sound Bit Error Rate Measurement

The bit error rate may be measured for an improved evaluation of the
Nicam signal sound quality.

Example

Calling up bit error measurement:

Press [2ndF] [SC]

Press [3]

In case there are no bit errors identified due to a strong signal,
BER=0.000 is indicated on the display.

In case there is hardly a signal or no signal at all received, OVERFLOW
is indicated on the display.

SC: 5.85 MHz

TV

BER=2.145E-05