Lenovo THINKSERVER 3797 User Manual

Page 114

Advertising
background image

Table 3. DSA diagnostic messages (continued)

v

Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.

v

See Chapter 7, “Parts listing, ThinkServer RD220 Type 3729, 3779, 3797, and 3798,” on page 231 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

Message
number

Component

Test

State

Description

Action

180-901-xxx

Check-point
panel

Check-
point panel
test

Failed

1. Check the operator information panel

cabling at both ends for loose or
broken connections or damage to the
cable. Replace the operator
information panel cable if it is
damaged.

2. Run the test again.

3. Replace the operator information panel

assembly (see “Removing the operator
information panel assembly” on page
160
and “Installing the operator
information panel assembly” on page
161).

4. Run the test again.

201-801-xxx

Memory

Memory
Test

Aborted

Test canceled:
the system
UEFI
programmed
the memory
controller with
an invalid
CBAR address

1. Turn off and restart the system.

2. Run the test again.

3. Make sure that the system UEFI code

is at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD section
for this component. For the latest level
of firmware, go to
http://www.ibm.com/support/
docview.wss?uid=psg1 MIGR-4JTS2T
and select your system to display a
matrix of available firmware.

4. Run the test again.

106

ThinkServer RD220 Types 3729, 3779, 3797, and 3798: Hardware Maintenance Manual

Advertising
This manual is related to the following products: