Completing the installation – Lenovo THINKSERVER 3797 User Manual

Page 235

Advertising
background image

To reinstall the system board, complete the following steps.

1. Align the system board as tilted shown, then rotate and lower it flat and slide it

back toward the rear of the server.

2. Reconnect to the system board the cables that you disconnected in step 11 of

“Removing the system board” on page 225.

3. Rotate the system board release latch toward the rear of the server until the

latch clicks into place.

4. Install the fans.

5. Install each microprocessor with its matching heat sink (see “Installing a

microprocessor and heat sink” on page 218).

6. Install the DIMMs (see “Installing a DIMM” on page 192).

7. Install the air baffles (see “Installing the DIMM air baffle” on page 178) and

“Installing the microprocessor 2 air baffle” on page 176.

8. Install the SAS riser-card and controller assembly (see “Installing the SAS riser

card and controller assembly” on page 202).

9. If necessary, install the Ethernet daughter card.

10. If necessary, install the virtual media key.

11. Install the PCI riser-card assemblies and all adapters (see “Installing a PCI

riser-card assembly” on page 168).

12. Install the cover (see “Installing the server cover” on page 160).

13. Push the power supplies back into the server.

14. Slide the server into the rack.

15. Reconnect the external cables; then, reconnect the power cords and turn on

the peripheral devices and the server.

Important: Either update the server with the latest SAS firmware or restore the
pre-existing firmware from a diskette or CD image.

Completing the installation

To complete the installation, complete the following steps:

1. If you removed the microprocessor 2 air baffle, replace the microprocessor 2 air

baffle (see “Installing the microprocessor 2 air baffle” on page 176) ).

2. If you removed the DIMM air baffle, install it now (see “Installing the DIMM air

baffle” on page 178).

3. If you removed either of the PCI riser-card assemblies, replace the riser-card

assemblies now (see “Installing a PCI riser-card assembly” on page 168).

Chapter 6. Removing and installing FRUs

227

Advertising