Table 3. DSA diagnostic messages (continued)

v

Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.

v

See Chapter 7, “Parts listing, ThinkServer RD220 Type 3729, 3779, 3797, and 3798,” on page 231 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

Message
number

Component

Test

State

Description

Action

Tape drive test
(Error
Messages
apply to results
of any of the 4
tests)

Presence
Test Self Test
Load Tape
Test Tape
Alert Check
Test

Failed

An error was
found in the
tape alert log
page.

1. Clean the tape drive, using the

appropriate cleaning media, and insert
new media.

2. Run the test again.

3. Clear the error log.

4. Run the test again.

5. Make sure that the drive firmware is at

the latest level. For the latest level of
drive firmware and software for tape
drives and libraries, go to
http://www.ibm.com/support/
docview.wss?uid=psg1TAPE-FILES.

6. Run the test again.

7. Note the tape alert flag that is returned

in the tape alert log. See “Tape alert
flags” on page 133.

8. Replace the tape drive if a hardware

failure is indicated.

9. If the failure remains, collect the data

from the DSA event log and send it to
IBM Service. For information about
contacting and sending data to IBM
Service, go tohttp://www.ibm.com/
support/
docview.wss?uid=psg1SERVCALL.