7. Reconnect the external cables; then, reconnect the power cords and turn on the

peripheral devices and the server.

Note: You must wait approximately 20 seconds after you connect the power

cord of the server to an electrical outlet before the power-control button
becomes active.

8. Start the Setup utility and reset the configuration.

v

Set the system date and time.

v

Set the power-on password.

v

Reconfigure the server.

Removing a heat-sink retention module

To remove a heat-sink retention module, complete the following steps:

1. Read the safety information that begins on page 3.

2. Turn off the server, and disconnect all power cords and external cables.

3. Remove the cover (see “Removing the cover” on page 159).

Attention:

In the following step, keep each heat sink paired with its

microprocessor for reinstallation.

4. Remove the applicable air baffle; then, remove the heat sink and

microprocessor. See “Removing a microprocessor and heat sink” on page 216
for instructions; then, continue with step 5.

5. Remove the four screws that secure the heat-sink retention module to the

system board; then, lift the heat-sink retention module from the system board.

6. If you are instructed to return the heat-sink retention module, follow all

packaging instructions, and use any packaging materials for shipping that are
supplied to you.

Installing a heat-sink retention module

To install a heat-sink retention module, complete the following steps:

1. Place the heat-sink retention module in the microprocessor location on the

system board.