7. Install PCI riser-card assembly 2.

8. Install the cover (see “Completing the installation” on page 227).

9. Slide the server into the rack.

10. Reconnect the external cables; then, reconnect the power cords and turn on

the peripheral devices and the server.

Removing the DIMM air baffle

When you work with some optional devices, you must first remove the DIMM air
baffle to access certain components or connectors on the system board. The
following illustration shows how to remove the DIMM air baffle.

1

DIMM air baffle

2

PCI riser-card assembly 1

To remove the DIMM air baffle, complete the following steps:

1. Read the safety information that begins on page 3.

2. Turn off the server and peripheral devices and disconnect all power cords and

external cables (see “Turning off the server” on page 53).

3. Remove the cover (see “Removing the cover” on page 159).

4. Remove PCI riser-card assembly 1 (see “Removing a PCI riser-card assembly”

on page 167).

5. Place your fingers under the front and back of the top of the air baffle; then, lift

the air baffle out of the server.

Attention:

For proper cooling and airflow, replace all air baffles before you

turn on the server. Operating the server with any air baffle removed might
damage server components.

Chapter 6. Removing and installing FRUs