Cooling Fans

120 VAC should now be at these fan

motors. If voltage is present,

check motors for shorts or opens.

WITH POWER OFF: Check for locked rotor.

Cooling fans continue

Cooling Fan Thermostat

Thermostat is normally open and may to run after

20 minute

have closed if control box temperature cool down

is 120°F or above.

Oven will not heat

Gas Supply

Check for adequate gas supply and

manual gas shut off valve is open.

Also, check flexible gas line connection.

Main Fan

If not operating, refer to “Oven Fan

Will Not Run” on Page C6.

Fuse 3 Amp

Check, replace if necessary.

Fuseholder

Check, replace if necessary.

Relay Oven Start

Supply voltage should be present

across these terminals.

Burner Switch

Check for supply voltage on both sides of

switch. If switch is closed and voltage

present on one side only, replace switch.

Gas Pressure Switch

This switch is located inside the gas

valve and should close when gas

pressure is present.

WITH POWER OFF: remove 3 prong plug

(on gas valve) and measure continuity between

terminals 2 and 3.

NOTE: Remove insulation pad below plug to

read numbers. If no continuity, check the

following:

Proper gas pressure supply to gas valve as

marked on the oven specification plate.

Check for proper adjustment of gas

pressure switch 8.8 on dial for

natural gas, 23 for LP, and

4.5 for Town Gas.

Check gas filter in gas valve for

blockage or damage. (See Adjustment

section for location)

If above checks are okay, but pressure

switch is still not closed, replace gas

valve.

Air Pressure

Check air switch terminals for supply voltage

Switch

at NO 2 and COM. If voltage is present on one

side only, check for air tube blockage or

misalignment. If these are okay, adjust

switch or replace necessary.

(Oven Cavity) High Limit

Terminals are normally closed,

Thermostat

opens at 660°F (350°C). If

open, push in reset button and retest.

If thermostat will not hold for

maximum oven temperature, and oven

is not exceeding temperature dial

setting, check for proper location of

capillary bulb in its spring holder.

If above check okay, replace hi-limit

thermostat.

Ignition Control

Check for proper supply voltage

to ignition control.