Lincoln Impinger Conveyor Ovens 1100 Series User Manual

Page 36

Advertising
background image

as follows:

220V - 30 ohms approximately

240V - 36 ohms approximately

Oven heats with switch off

Mercury Contactor

The mercury contactor has probably

malfunctioned in the closed position. If

there is no voltage to the operating coil,

but there is high voltage at the contactor

output, replace the mercury contactor.

Intermittent Heating

Thermal/Overload

The main fan motor is equipped with

of motor

internal thermal protection and will

cease to operate if overheating

occurs. As the motor overheats and

then cools, this will cause the oven to

cycle on and off intermittently. This

may be caused by improper ventilation

or preventative maintenance. Also,

most of the problems listed under

“Oven will not heat” can cause

intermittent failure.

Conveyor will not run

REFER TO PAGE 31

Conveyor speed varying

REFER TO PAGE 32

or intermittent

Time/Temp Display

REFER TO PAGE 33

inoperative

Temp Display out or

REFER TO PAGE 33

inaccurate

Impinger II - 1100 Series Service Manual - International

36