Lincoln Impinger Conveyor Ovens 1100 Series User Manual

Page 65

Advertising
background image

Blue

Gray

Red

Brown

Red

POWER

J 5

J 4

J 3

J 1

J 6

LOCKED ROTOR

To T/T display

POTENTIOMETER

Max.
Conveyor
Speed Adj.

Min.
Conveyor
Speed Adj.

TIME/TEMP

Black to #4
White to #7

ON

1

2

3

4

5

CURRENT SENSE
DO NOT ADJUST

Heat Sink

MOTOR

1. With power off, the five (5) dip switches located on the conveyor control (see drawing above ) should be set as

below.

DIP SWITCHES FOR 50 SEC. TO 30 MIN. TIMES

CONTROL

1

2

3

4

5

SWITCH POSITION

OFF OFF

ON

OFF

OFF

DIP SWITCHES FOR 23 SEC. TO 30 MIN. TIMES

CONTROL

1

2

3

4

5

SWITCH POSITION

OFF ON

OFF

OFF

OFF

2. With power off, the ten (10) dip switches located on rear of Time/Temp Display (see drawing on page D15)

should be set as below.

NOTE: For time/temp displays using a thermister (2 yellow wires on Terminals 9 & 10), set the dip switches as

follows:

FOR 50 SEC TO 30 MIN CONVEYOR TIMES

DISPLAY

1

2

3

4

5

6

7

8

9

10

SWITCH POSITION

OFF

*

*

ON

ON

OFF

OFF

ON

OFF

ON

Impinger II - 1100 Series Service Manual - International