TROUBLESHOOTING GUIDE ELECTRIC OVEN

MODEL 1151 200 VAC THREE PHASE 60 HZ

REFER TO PROPER SCHEMATIC FOR INDENTIFIED COMPONENTS

SYMPTON

POSSIBLE CAUSE

EVALUATION

Oven fan will not run

Incoming Power Supply

Check circuit breakers. Reset if required.

Call Power Co. if needed.

Fuses,10 Amp,Main Fan

Check, replace if necessary.

Fuseholder

Check, replace if necessary.

Fuses, 1 Amp,

Check, replace if necessary.

Transformer

Fuseholder

Check, replace if necessary.

Transformer, Control

120 VAC ± 10% should be present

at secondary of transformer. If

proper voltage is not present, check

transformer primary for proper

input. Replace as needed.

Thermostat, High Limit,

Terminals are normally closed. If open,

Oven Cavity

reset the thermostat and test for proper

operation. If it will not reset and hold,

replace thermostat.

Switch, Main

Check for continuity between switch

Fan

terminals.

Relay, Oven Start

Check for continuity at relay coil, and

visually check for pull in of contacts.

20 Minute Time Delay

Check for 120 VAC at terminals #1 to

neutral on 20 minute Time Delay Relay.

If no voltage is present, trace wiring

back to power source. If voltage is

present at terminal #1, check for 120

VAC at terminal #2 to neutral. If no voltage is

present, and Main Fan Switch is closed, replace

Time Delay.

Main Fan Relay

Check for 120 VAC to coil of the Relay.

If no voltage is present, trace wiring

back to 20 minute Time Delay Relay. If

voltage is present, check to insure

contacts are closing.

Main Fan Motor

Check for opens, shorts, or grounds.

WITH POWER OFF: Turn fan blade to

check for locked rotor.

Capacitor

Check for opens, shorts, or grounds.

No main fan cool down

20 Minute Time Delay

Check for 120 VAC at terminal #2 to

neutral while oven is “on”. Turn off the

main fan switch, 120 VAC should

continue to be present for 20 minutes.

If voltage is not present for

approximately 20 minutes, replace the

timer.

Impinger II - 1100 Series Service Manual - International