TROUBLE SHOOTING GUIDE

ELECTRIC OVENS

MODEL 1104

380/220 VAC

THREE PHASE

50 HZ

MODEL 1105

415/240 VAC

THREE PHASE

50 HZ

MODEL 1106

240 VAC

SINGLE PHASE

50 HZ

REFER TO PROPER SCHEMATIC FOR IDENTIFIED COMPONENTS

SYMPTON

POSSIBLE CAUSE

EVALUATION

Oven fan will not run

Incoming Power Supply

Check circuit breakers. Reset if required.

Call Power Co. if needed.

Fuse, 1 Amp,

Check, replace if necessary.

Fuseholder

Check, replace if necessary.

Switch, Main Fan

Check for continuity between switch terminals.

Transformer, Control

120 VAC ± 10% should be present

at secondary of transformer. If proper voltage is not

present, check transformer primary for proper input.

Replace as needed.

Main Fan Relay

Check continuity to 120 VAC coil. Check

for power to relay coil (120 VAC). Check for 220/240

VAC to the relay terminals. Check, replace

if necessary.

Fuse 10 A. Main Fan

Check, replace if necessary.

Fuse Holder

Check, replace if necessary.

Main Fan Motor

Check for opens, shorts, or grounds.

WITH POWER OFF: Turn fan blade to

check for locked rotor.

Capacitor

Check for opens, shorts, or grounds.

No control box cooling

Check for main fan operation. If not operating, refer

to “Oven fan will not run”.

Cooling Fan Motor

120 VAC should be present at the fan motor. If

voltage is present, check for opens or shorts.

WITH POWER OFF: Check for locked rotor

on fan motor.

No main fan cool down

Cool Down Thermostat

Check cool down thermostat (thermostat

closes at 160°F and opens at 140°F).

Check for power (220/240 VAC) at cool down thermo

stat. With cool down thermostat preheated, check for

continuity. If switch is open, replace.

Oven will not heat

Main Fan Motor

Check for main fan operation. If it is not

operating, refer to “Oven fan will not run”.

High Limit Thermostat,

Terminals are normally closed (open at

190°F). If open, reset the thermostat and

test for proper operation. If it will not reset and hold,

then replace.

Impinger II - 1100 Series Service Manual - International