Lincoln Impinger Conveyor Ovens 1100 Series User Manual

Page 67

Advertising
background image

HALL EFFECT SENSOR - REPLACEMENT

Remove two (2) mounting screws and

remove sensor from conveyor motor. Reinstall in

reverse order.

+

-

1 2

gnd

3

3

2

gnd

FILTER
COVER
PLATE

FILTER
COVER
PLATE

PRESSURE
CONTROLLER
ADJUSTMENT

MANIFOLD
PRESSURE
ADJUSTMENT

OUTPUT

ELECTRICAL
CONNECTOR

ELECTRICAL
CONNECTOR

TOP VIEW

SIDE VIEW

THE FOLLOWING COMPONENTS ARE USED FOR MODEL 1152-1158 ONLY

GAS VALVE, MULTI BLOCK FOR MODELS 1152 Through 1158

REMOVAL PROCEDURE:

1. Turn off power at the circuit breaker panel.

2. Turn off gas in main line before the flexible hose.

3. Remove control compartment covers.

4. Remove 4 screws from bulkhead plate on back of oven at gas pipe.

5. Remove gas pipe and bulkhead plate from gas valve.

6. Remove the 2 electrical plugs from the gas valve.

7. Unscrew the aluminum tubing connector from the gas valve.

8. Remove the cross brace from the top of the control cabinet.

9. Unscrew the pipe union and remove the gas valve.

10. Reassemble in reverse order and check for gas leaks.

ADJUSTMENT PROCEDURE - Refer to drawing above:

1. Remove the plastic cover (2 screws) exposing the pressure controller adjustment dial and adjust as follows:

NATURAL GAS

LP GAS

CITY/TOWN GAS

PRESSURE CONTROLLER

DIAL SETTINGS

8.8

23

4.5

2. Install a test manometer in the gas line between the gas valve and burner orifice. The test plug is located in the

gas line just below and on the burner side of the solenoid valve. The output manifold pressure adjustment is

made with a slotted screw located under a swivel cover marked “DRUCKREGLER”.The following chart is

provided for manifold pressure adjustment, However, always, refer to the Oven Identification Plate to be sure

the proper type of gas and pressure for that specific oven are being used.

Impinger II - 1100 Series Service Manual - International

67

Advertising