Lincoln Impinger Conveyor Ovens 1100 Series User Manual

Page 28

Advertising
background image

Check for proper line voltage to

the Burner Blower Motor. This

can be checked at motor connecting

plug terminal 2 and 5. If voltage is

present proceed with next step, if not,

wait 30 seconds, push reset button,

and try to restart. If this fails, check

wires from Thermostat and Burner

Blower Motor to the Ignition Control.

If all above fails and wires are okay,

replace ignition control.

Burner Blower Motor

Check for supply voltage to motor.

WITH POWER OFF: turn blower wheel

to check for locked rotor.

If proper supply voltage is present at

motor connecting plug, terminal 2

and 5 and motor does not run, replace motor

Air Pressure

Check for proper supply voltage

Switch

switching from “N.C.” to “N.O.” as air

(Burner Blower)

pressure switch closes.

If above fails, connect a temporary

jumper wire (FOR TESTING ONLY)

from terminal “C” to terminal “N.O.”

on ignition control (bypasses air

switch). NOTE: For Honeywell

control only.

Check for air switch adjustment,

air tube blockage, or misalignment,

and if these fail,replace air pressure switch

Spark Generator

A pre-purge-time of 30 to 60 seconds

occurs after blower motor starts, check for supply

voltage atspark generator.

If voltage is not present, check reset

button for the Ignition Control.

If voltage is still not present, replace

ignition control.

If voltage is present, visually check

for spark at ignitor head located in

burner.

Ignitor/Sensor Assembly

Check this assembly for visible

damage. If there is no damage, replace

the Spark Generator. If there is

damage, replace the Ignitor/Sensor

Assembly. Also check for frayed or

damaged wires in the burner tube.

Gas Valve

Gas valve should open when

proper supply voltage is present.

If no voltage is present, check the

reset button on the ignition

control, and all connections for

tightness. If there is still no

voltage present at gas valve, replace ignition

control.If there is voltage present, check for

gas pressure at the gas pressure tap

located in the gas piping just prior to

the burner. If there is no gas pressure, replace

gas valve

Impinger II - 1100 Series Service Manual - International

28