changing a board or tach. This test is not always

100% accurate as this test is not performed at

operating speeds. However, this test is the best

method currently available. Readjustment should

always be attempted at least once before replace-

ment. See procedure for board adjustment in

Section D.

DC Gearmotor

If the problem seems to be the motor or gearbox.

Check the brushes in the motor for excessive

arcing and/or unusual wear. Check the motor

and gearbox from instructions located under

“possible cause” listing “Conveyor gear motor”.

Time/Temp Display

12.6 VAC Power

Measure the transformer primary

inoperative

Supply

for a nominal 120 VAC input.

If 120 VAC primary voltage is not available, refer

to the schematic and trace the circuit for incomi

ng power failure

S/N 2011821 & Above

Measure the secondary voltage

Refer to Page 45

output which will be 12.5 to 15

VAC normally. Recheck secondary

output at rear of Time/Temp

Display. Terminals 1 to 3 should

read 12.5 to 15 VAC. Terminals

1 to 2 and 2 to 3 should be

1/2 of the reading across 1 to 3.

If you do not get the above

secondary readings, replace the

transformer. The older units have a 4 amp

ambient fuse in each red secondary lead.

These may be jumpered to determine if they

are burnt out or intermittent.

Temp Display out or

NOTE: Time/Temp displays

Insert the thermocouple of your

erratic

uses two types of temperature

pyrometer into a finger hole in the top

sensor, Thermistor Probe -

center of the oven. The thermocouple

2 yellow wires, Thermo-

tip should measure air temperature

couple Probe - 1 red wire

and must not be touching metal.

and 1 white wire

Disconnect the yellow tipped thermistor

leads from the time/temp. terminals 9 &10

Thermistor Probe

Measure the resistance of the thermistor

probe See the chart in Section D for proper
resistance readings.

Inspect the thermistor

bulb for itsproper location in its spring

holder.Check for short in leads where they

enter the sensor bulb. Also check each

thermistor lead for short toground.

Thermocouple Probe

Connect temperature meter to

thermocouple at terminals 9 and 10 on back

of the time/temp display. (Be sure tomaintain

proper polarity on therocouple connections.)

Compare actual oventemperature with the

reading at the time/temp display. If the

temperature readings match, re-calibrate or

replace time/temp

Impinger II - 1100 Series Service Manual - International

32