INSTALLATION

IDEALARC DC-1000

A-9

CONNECTION FOR AIR/CARBON ARC
CUTTING OPERATION

THE OUTPUT TERMINALS ARE ENERGIZED AT
ALL TIMES WHEN THE IDEALARC DC-1000 IS
CONNECTED FOR AIR/CARBON ARC CUTTING.

____________________________________________________

1.

Set ON/OFF PUSH BUTTON to OFF.

2.

Locate and open the access door on the Front
Case Assembly.

3.

If necessary, disconnect all wire feeder control
cable connections from the DC-1000 terminal
strip.

4.

Remove the leads from the unit by pulling them
through and out of the strain relief box connector
(s).

5.

Connect a jumper wire from terminal #2 to termi-
nal #4 on the terminal strip.

6.

Set the Welding Mode Switch to the CV(I) position
for air/carbon arc cutting.