MAIN TRANSFORMER (T1) VOLTAGE TEST

IDEALARC DC-1000

TEST DESCRIPTION

This test will determine if the correct voltages are being:
a.

applied to the primary windings of the Main Transformer (T1).

b.

induced on the secondary winding, auxillary windings, and phase angle windings.

MATERIALS NEEDED

Volt/Ohm Meter (Multimeter)
IDEALARC DC-1000 wiring diagrams (See Electrical Diagram Section of Manual).