F-24

TROUBLESHOOTING & REPAIR

F-24

FIRING BOARD TEST

IDEALARC DC-1000

TABLE F.1 - LED 7, 8 and 9 Check List

IF

LED 7 is ON

LED 7 is OFF or is DIM-
MER than other LEDs

LED 8 is ON

LED 8 is OFF or is DIM-
MER than other LEDs

LED 9 is ON

LED 9 is OFF or is DIM-
MER than other LEDs

THEN

AC power is being supplied to the Firing Board from
leads #203 and #204 connected to the phase angle wind-
ing in the Main Transformer.

The proper AC voltage may not be reaching Firing Board.
Check for loose or faulty connections.

Perform Main

Transformer Test.

AC power is being supplied to the Firing Board from
leads #205 and #206 connected to the phase angle wind-
ing in the Main Transformer.

The proper AC voltage may not be reaching Firing Board.
Check for loose or faulty connections.

Perform Main

Transformer Test.

AC power is being supplied to the Firing Board from
leads #207 and #208 connected to the phase angle wind-
ing in the Main Transformer.

The proper AC voltage may not be reaching Firing Board.
Check for loose or faulty connections.

Perform Main

Transformer Test.