If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric
Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

F-4

TROUBLESHOOTING & REPAIR

F-4

IDEALARC DC-1000

Observe all Safety Guidelines detailed throughout this manual

OUTPUT PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

Major Physical or Electrical
Damage is Evident.

The Machine is dead - The Input
contactor does not operate.

Input contactor (1CR) chatters.

1. The.Start/Stop button (S1)

may be faulty- Check for prop-
er operation. See wiring dia-
gram.

2. The Control Transformer (T2)

may be faulty. Perform the
Control Transformer Test.

3. The primary or secondary

thermostats may be open.
Check or replace. Also check
the associated wiring. See
wiring diagram.

4. The pilot relay (2CR) may be

faulty. Check or replace. See
wiring diagram.

5. The input contactor coil may

be open. See wiring diagram.

6. The Control board may be

faulty - Replace.

1. The pilot relay (2CR) may

have bad contacts. Check or
replace relay.

2. Check for loose or faulty

wiring between pilot relay
(2CR) and input contactor
(1CR) coil connections.

3. The input contactor (1CR)

may be faulty - Replace.

Contact the Lincoln Electric

Service Dept. (216) 383-2531
or 1-800-833-9353 (WELD)

1. Check for blown or missing

fuses in input lines.

2. Check the three-phase input

line voltage at the machine.
The input voltage must match
the rating plate and reconnect
panel.

1. The input line voltage may be

low. Check all three phases.

2. Make sure input line voltage

matches machine rating and
reconnect panel.

CAUTION