F-8

TROUBLESHOOTING & REPAIR

F-8

IDEALARC DC-1000

Observe all Safety Guidelines detailed throughout this manual

OUTPUT PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

The machine does not have max-
imum weld output.

1. Check all three-phase input

lines at the DC-1000. Make
sure input voltages match
machine rating and reconnect
panel.

2. Put output control switch

(SW3) in “OUTPUT CON-
TROL AT DC-1000” position.
If problem is solved, then
check remote control unit or
wire feeder.

1. Check the output control

potentiometer (R1) and asso-
ciated circuitry for loose or
faulty connections. See wiring
diagram.

2. Perform

Control Board Test.

3. Perform

Firing Board test.

4. Perform

Main Transformer

Test.

5. Perform

SCR Output Bridge

Test.

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric
Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.