Innershield mode, Troubleshooting & repair – Lincoln Electric IDEALARC DC 1000 SVM123-A User Manual

Page 81

Advertising
background image

F-41

TROUBLESHOOTING & REPAIR

TYPICAL OUTPUT VOLTAGE WAVEFORM -MACHINE

LOADED CONSTANT VOLTAGE INNERSHIELD MODE

IDEALARC DC-1000

Volts/Div. . . . . . . . . . . . . 20 V/Div.
Horizontal Sweep . . . . . 2 ms/Div.
Coupling . . . . . . . . . . . . . . . . . DC
Trigger . . . . . . . . . . . . . . . Internal

SCOPE SETTINGS

F-41

This is the typical DC open circuit volt-
age waveform generated from a proper-
ly operating machine. Note that each
vertical division represents 20 volts and
that each horizontal division represents
2 milliseconds in time. The machine
was loaded with a resistance grid bank.
The grid bank meters read 600 amps at
44 VDC.

Note: Scope probes connected at
machine ouput terminals: (+) probe to
positive 1000 Amp terminal, (-) probe to
negative terminal.