Operation – Lincoln Electric IDEALARC DC 1000 SVM123-A User Manual
Page 20

B-4
OPERATION
B-4
•
Three circuit solid state control system provides
maximum performance and circuit protection.
•
Low profile case provides maximum use of space.
•
Convenient access to all controls.
•
Large output lead strain relief openings to prevent
terminal and cable damage.
•
Easily removed case side, even when stacked.
•
Enclosure designed with air intake louvers that
keep dripping water from entering the unit, allow-
ing outdoor operation. Transformer, SCR bridge,
and choke have special corrosion resistant paint
for added protection.
IDEALARC DC-1000
WELDING CAPABILITY
The IDEALARC DC-1000 has the following duty cycle ratings.
If the duty cycle is exceeded, the thermal protective thermostat will shut off the output of the machine by keeping
the input contactor open until the machine cools to normal operating temperature. The machine can then be
restarted by pushing the ON/OFF push button.
Duty Cycle
Amps
Volts
Hertz
55% (Based on 10 min.)
1250
44
50/60
60% (Based on 10 min.)
1140
44
50/60
100%
1000
44
50/60