Innershield - minimum output setting - no load, Troubleshooting & repair – Lincoln Electric IDEALARC DC 1000 SVM123-A User Manual
Page 80
Advertising
F-40
TROUBLESHOOTING & REPAIR
F-40
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM
CONSTANT VOLTAGE INNERSHIELD
MINIMUM OUTPUT SETTING - NO LOAD
IDEALARC DC-1000
Volts/Div. . . . . . . . . . . . . 50 V/Div.
Horizontal Sweep . . . . . 2 ms/Div.
Coupling . . . . . . . . . . . . . . . . . DC
Trigger . . . . . . . . . . . . . . . Internal
SCOPE SETTINGS
This is the typical DC open circuit volt-
age waveform generated from a proper-
ly operating machine. Note that each
vertical division represents 50 volts and
that each horizontal division represents
2 milliseconds in time.
Note: Scope probes connected at
machine output terminals: (+) probe to
positive 1000 Amp terminal, (-) probe to
negative terminal