Duty Cycle

Amps

Volts at Rated Amperes

100%

1000

44

60%

1140

44

55%

1250

44

Mode

Current Range

Maximum Open

Auxiliary

Constant Current

140 to 1250 Amps

Circuit Voltage

Power

Constant Voltage

140 to 1250 Amps

75 VDC

115 VAC, 8 Amps

Constant Voltage

140 to 625 Amps

(@500 Amp Stud)

IDEALARC DC-1000

A-2

INSTALLATION

TECHNICAL SPECIFICATIONS – IDEALARC DC - 1000

INPUT - THREE PHASE ONLY

RATED OUTPUT

OUTPUT

RECOMMENDED INPUT WIRE AND FUSE SIZES

Standard Voltage

Input Current at Rated Output

230/460/575

193/96.5/77

Input

Voltage/Frequency

Fuse (Super Lag)

or Breaker Size

Input Ampere Rating on

Nameplate

Type 75C Copper

Wire in Conduit

AWG (IEC) Sizes

230/60

300

193

430/60

150

96.5

575/60

125

77

000 (85mm2)

3 (26.7mm2)

6 (16mm2)

4 (25mm2)

6 (16mm2)

6 (16mm2)

Type 75C Copper

Ground Wire in

Conduit AWG (IEC)

Sizes

Height

Width

Depth

Weight

30.75 in

22.25 in

38.0 in

821 Ibs

(781 mm)

(567 mm)

(965 mm)

(372 kg)

PHYSICAL DIMENSIONS