Installation, Technical specifications – idealarc dc - 1000 – Lincoln Electric IDEALARC DC 1000 SVM123-A User Manual
Page 8

Duty Cycle
Amps
Volts at Rated Amperes
100%
1000
44
60%
1140
44
55%
1250
44
Mode
Current Range
Maximum Open
Auxiliary
Constant Current
140 to 1250 Amps
Circuit Voltage
Power
Constant Voltage
140 to 1250 Amps
75 VDC
115 VAC, 8 Amps
Constant Voltage
140 to 625 Amps
(@500 Amp Stud)
IDEALARC DC-1000
A-2
INSTALLATION
TECHNICAL SPECIFICATIONS – IDEALARC DC - 1000
INPUT - THREE PHASE ONLY
RATED OUTPUT
OUTPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES
Standard Voltage
Input Current at Rated Output
230/460/575
193/96.5/77
Input
Voltage/Frequency
Fuse (Super Lag)
or Breaker Size
Input Ampere Rating on
Nameplate
Type 75C Copper
Wire in Conduit
AWG (IEC) Sizes
230/60
300
193
430/60
150
96.5
575/60
125
77
000 (85mm2)
3 (26.7mm2)
6 (16mm2)
4 (25mm2)
6 (16mm2)
6 (16mm2)
Type 75C Copper
Ground Wire in
Conduit AWG (IEC)
Sizes
Height
Width
Depth
Weight
30.75 in
22.25 in
38.0 in
821 Ibs
(781 mm)
(567 mm)
(965 mm)
(372 kg)
PHYSICAL DIMENSIONS
A-2