TROUBLESHOOTING & REPAIR

F-12

IDEALARC DC-1000

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric
Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

WELDING PROBLEMS

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

Poor performance (including arc
outages) while welding at low
current (less than 450 amps)
when connected to 1000 amp (+)
output terminals.

The machine frequently shuts off
while using the 500 amp (+) out-
put terminal (later models only).

1. Change the welding cable(s)

to the 500 amp terminal (later
models only).

1.The output current demand

may be over 500 amps, caus-
ing the choke to overheat.
Change the welding cable(s)
to the 1000 amp output termi-
nals.

1. The choke thermostat may be

faulty - Replace.

CAUTION