LENNOX HEARTH PRODUCTS • ESTATE™ SERIES WOOD-BURNING FIREPLACES • MODELS EST-36, EST-42, EST-50 • INSTALLATION INSTRUCTIONS

step 4. Note: Chimney sections are constructed

with a unique locking tab design, which ensures

an immediate, tight assembly between sections.

Plan your chimney requirements carefully before

assembly as chimney is difficult to disassemble

after installation. If disassembled, the tabs might

become damaged. Be certain tabs are properly

formed to ensure locking tabs engage properly.

Security Chimneys FTF10 and FTF13 chimney

systems are a two piece chimney, which snap

together from the fireplace up. Start with the

inner flue section with the lanced end up, snap

lock it in to the matching collar on top of the

fireplace. At all subsequent joints, the upper flue

section fits into the preceding flue section. Each

piece snaps together by means of locking tabs

(9 locking tabs per joint). Check each piece by

pulling up slightly from the top to ensure proper

engagement before installing the next section.

If the flue has been installed correctly, it will not

separate when you test it. Also, the inner flue

joint where each section is joined should be

tight and flat without gaps (Figure 24).

FTF8-S4 Stabilizer

Figure 24

Locking

Tabs

(Lances)

Figure 25

Install the Model FTF10-S4 stabilizer by fitting

inner section down into respective section of

proceeding flue pipe and locking outer stabilizer

section into place over the outer chimney pipe.

Position for proper clearance through framed

opening and nail straps securely (under tension

in “shear”) into place on framing. Use 8d nails.

Attach successive lengths of chimney pipe

directly to stabilizer using same techniques as

described in Step 4 (Figure 27).

Figure 27

Note: Assemble one component of chimney at

a time (inner section first, then outer section

last) before proceeding with the next complete

section.

Continue to assemble the chimney up through

framed opening. Assemble just enough to

penetrate the roof flashing openings (Figure

26). Always maintain 2" minimum air space

to combustible materials and always check

each chimney joint (inner and outer) to ensure

proper engagement. Check vertical alignment

of chimney so that it projects from the roof in

true vertical position.

Outer pipe section installs in just the opposite

way; the lanced end goes down and each new

section goes OVER the outside of the previous

section installed (Figure 25).

For Canada Only

When installing the chimney system through

an open attic space, the attic shield assembly-

firestop spacer must be used (Figure 23). This

installation procedure is listed and approved

by Warnock Hersey, Inc., and only required

for use in Canada.

Figure 23

Open Attic Space

Figure 26

Chimney sections from Security Chimneys do

not need to be screwed together. Additional

reinforcement is not necessary except in cer-

tain offset conditions (refer to Figure 38 on

page 16).

step 5. The height of vertical chimney pipe

supported only by the fireplace must not

exceed 30'. Chimney heights above 30' must

be supported by a Model FTF10-S4 stabilizer,

installed at 30' intervals.

Note: The Model FTF10-S4 adds 3" net effective

height to the total chimney system.

2" (51mm) Min. Air Space

to Combustibles

Note: Do not apply excessive pressure to any

subsequent chimney sections following the

stabilizer when installing. Ensure each subse-

quent chimney section is securely attached by

testing as noted in Step 4.

step 6. Select the proper Security Chimneys

roof flashing based on pitch of roof. Use chart

below for selection:

roof pitch

model

flat to 6/12

F10F6

6/12 to 12/12

F10F12

Next, slide roof flashing over extended chimney

section that previously has been installed above

the roof opening in Step 4. FTF10 flashings

require flashing spacers. Slide flashing all the

way down until the flashing base rests flat on

the roof (Figure 28). Again, check the vertical

position of the chimney and the 2" minimum

air space to combustibles.

Figure 28

Note: Do not caulk or seal the ventilating

openings.

FTF10 Chimney

FTF10 Flashing

Flashing Spacers

Do Not Seal