Lennox Hearth WOOD-BURNING FIREPLACES EST-50* User Manual

Page 9

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

9

LENNOX HEARTH PRODUCTS • ESTATE™ SERIES WOOD-BURNING FIREPLACES • MODELS EST-36, EST-42, EST-50 • INSTALLATION INSTRUCTIONS

Figure 7-2

Figure 7-1

InstallIng thE fIrEplacE

step 1. Slide the fireplace into prepared fram-

ing or position fireplace in its final position

and frame later.

step 2. Insert the metal safety strips, pack-

aged with the fireplace, beneath the fireplace,

as illustrated in Figures 7-1 and 7-2, below).

The safety strips should overlap 1" (25 mm) for

continual coverage of the floor.

Note:
• Safety strips are not required when fireplace

rests on a noncombustible surface.

• Install the hearth extension only as illustrated.

The safety strips should extend from front and

sides of the fireplace 2" (51 mm). In the event a

wooden support is used to elevate the fireplace

above the floor, a “Z” type safety strip should

be fabricated and used to protect the front

surface of the wood support as well as the

floor beneath the hearth extension (see Figures

8 and 9, below). The safety strips should be

tacked down to prevent possible movement.

Note: The “Z” type safety strip is not supplied.

Combustible

Wall

Metal

Safety Strip

Hearth

Extension

Floor

1"

(25mm)

Zero Clearence

to Rear and

Side Spacers

Combustible

Wall

Metal

Safety

Strip

Hearth

Extension

Floor

Platform

1"

(25mm)

step 3. Refer to fireplace drawings and spe-

ci fications on pages 10 and 11 for framing

dimensions and details. Frame appliance

enclosure as illustrated in Figures 12 through

15 on page 11.

Important:
• nEVEr rEmoVE or modIfy thE

fIrEplacE top spacErs undEr any

cIrcumstancEs.

• nEVEr notch thE hEadEr to fIt

around thE spacErs.

• nEVEr Install thE hEadEr loWEr

than thE spacErs.

• thE hEadEr may bE In dIrEct contact

WIth thE top spacErs but may not bE

supportEd by thEm.

step 4. Fireplace may be anchored to floor.

Bend down four (4) anchor tabs located at the

base of the fireplace and secure to the floor by

nailing with 8d nails (Figure 10, below).

Figure 8

Figure 9

Figure 10

Anchor

Tab

Metal Safety Strips

with 1" (25mm)

Overlap

2"

(51mm)

Special Z Metal

Safety Strips with 1"

(25mm) Overlap

2"

(51mm)

Blocking

Platform

Advertising
This manual is related to the following products: