NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

5

LENNOX HEARTH PRODUCTS • ESTATE™ SERIES WOOD-BURNING FIREPLACES • MODELS EST-36, EST-42, EST-50 • INSTALLATION INSTRUCTIONS

cautIon: do not blocK thE hEat-cIr-

culatIng aIr InlEt and outlEt ports

on cIrculatIng modEls. doIng so may

rEsult In a potEntIal fIrE hazard.

If you plan to raise the fireplace and hearth

extension, build the platform assembly, then

position fireplace and hearth extension on

top. Secure the platform to the floor to prevent

possible shifting.

clEarancEs

Minimum clearance to combustibles for the

Estate fireplace is as follows; sides and back –

1" (25.4 mm), combustible floor – 0" (0 mm),

adjacent wall 18" (457 mm), adjacent shielded

wall (K factor of .84 or less 24" W x 36" H) 12"

(305 mm), ceiling – 37-1/2" (953 mm).

Note: Clearance at the nailing flange for both

fireplace models is 0" (0mm).

Note: Adjacent wall considerations are for

an adjacent wall on only a single side. Walls

should not be placed at minimum distance at

both sides of the fireplace.

assEmbly stEps

Note: The following steps represent the normal

sequence of installation. Each installation is

unique, however, and may require a different

sequence.

1. Position firebox prior to framing or into

prepared framing.

2. Install Cold Climate Kit (Canada only).

3. Install the chimney system.

4. Install optional outside combustion air kit.

5. Plumb gas line if a decorative gas appliance

will be used. (Gas connections should only be

performed by an experienced, licensed/certified

tradesman.)

6. Complete the installation; finish wall mate-

rial, surround and hearth extension to your

individual taste.

7. Assemble and attach optional glass door

assembly.

See Figure 1 on page 3 for a general idea of

each element of the fireplace system.

Figure 5

prE-InstallatIon notEs

The fireplace may be installed directly on a

combustible floor or raised on a platform of

an appropriate height. Do not place fireplace on

carpeting, vinyl or other soft floor coverings. It

may, however, be placed on flat wood, plywood,

particle board or other hard surfaces.

Be sure fireplace rests on a solid continuous

floor or platform with appropriate framing for

support and so that no cold air can enter the

room from under the fireplace.

The fireplace may be positioned and then the

framing built around it, or the framing may be

constructed and the fireplace positioned into

the opening.

Usually, no special floor support is needed for

the fireplace, however, to be certain:

1. Estimate the total weight of the fireplace

system including chimney and surround ma-

terials such as brick, stone, etc., to be installed.

Shipping weights for the fireplace may be found

on page 23.

2. Measure the square footage of the floor space

to be occupied by the system, surrounds and

hearth extensions.

3. Note the floor construction, i.e., 2 x 6’s,

2 x 8’s or 2 x 10’s, single or double joists, type

and thickness of floor boards.

4. Use this information and consult your local

building code to determine if you need ad-

ditional support.

Wall

Covering

Black Portion Of Frame

Not To Be Covered With

Combustible Materials

Safe

Zone

15

°

4-3/4”

18”

Door

Opening

1/2

NOTE: Do NOT permanently place furniture or

other items such as decorative pillows within

60" of the fireplace front face.

prE-assEmbly stEps
EST-50:

Install the outer transition assembly

before installing the fireplace. See “Installating

the EST-50 Outer Transition Assembly” (next

page).

EST-36 and EST-42:

See Figure 6, below.

Remove all items packed under the grate and

set aside for later installation. Cut the two wire

ties securing the grate, and discard the ties.

Remove the grate, and set aside for later instal-

lation. Using a 1/4" nut driver, remove the two

tie brackets from the firebox floor, and discard

the tie brackets.

Figure 6: EST-36 and EST-42 Assembly

screen rods

Wire (mesh) firescreens

grate brackets

grate

Cut the wire ties holding the grate to

the firebox floor, and remove the grate.
Use a 1/4" nut driver to remove the

screws from the tie brackets.
Discard wire ties and tie brackets

after removal.