Offset calculations – Lennox Hearth WOOD-BURNING FIREPLACES EST-50* User Manual

Page 16

Advertising
background image

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

16

LENNOX HEARTH PRODUCTS • ESTATE™ SERIES WOOD-BURNING FIREPLACES • MODELS EST-36, EST-42, EST-50 • INSTALLATION INSTRUCTIONS

Figure 38

Figure 40

offsEt calculatIons

step 1. Use Offset Chart to determine amount of

horizontal offset (A) and height (B) for various

chimney section assemblies.

step 2. Use “Height of Chimney Only” column

in The Vertical Elevation Chart to determine

combinations of chimney used above return

elbow to achieve desired heights. Reference

Components Effective Height Chart in vertical

elevation chart section.

step 3. Use Elevation Chart as job estimator only.

Add necessary firestop spacers and stabilizers

as required. Firestop spacers must be used as

shown in Figures 21 and 22 and stabilizers as

shown in Figure 27.

Figure 36

Stabilizer

A

1

20’ Max.

(6m)

B

1

10’ Max.

(3m)

Figure 37

A

1

C

1

B

1

B

2

C

2

A

2

A

1

C

1

B

1

B

2

C

2

A

2

Figure 39

FTF10 Chimney

Joints

No. 8 x 1/2" SMS

Screw

s R

equired at

Ever

y Joint Past 6’

No Screw

s R

equired in

Joints for First 6’ of

Offset

4’ (1.2m)

6’ (1.8m)

Underside of Chimney

FTF10-E30*

Return Elbow

FTF10 Chimney

Section (s)

FTF10-30*

Offset Elbow

A

B

65-1/4"

(1657mm)

* Part of Offset/Return Package, Model FTF10-ES30

Advertising
This manual is related to the following products: