NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

7

LENNOX HEARTH PRODUCTS • ESTATE™ SERIES WOOD-BURNING FIREPLACES • MODELS EST-36, EST-42, EST-50 • INSTALLATION INSTRUCTIONS

step 4. attach damper link to damper bracket on inner

transition collar.

4.1. Turn the inner transition collar upside down, and attach the damper

link to the damper bracket with the enclosed 1/4-20 bolt and nut,

as shown in Figure A-6, below.

4.2. Using two 7/16" wrenches, tighten the nut completely (Figure

A-7, below).

4.3.

After tightening the nut, loosen it 1/2-turn.

Figure A-6

Figure A-7

Inner Transition Collar

(upside down)

step 5. attach damper assembly to inner transition flange.

5.1. See Figure 8, below. Insert the damper link through the inner

transition flange, and then place the inner transition collar over the

inner transition flange.

5.2. See Figure A-9, below. Align the notch in the rear of the inner

transition collar with the dimple in the rear of the inner transition.

5.3. Using a rubber mallet, gently tap the damper assembly (at the top

of the inner transition collar) until all screw holes align.

5.4. See Figure A-10, below. Using a 5/16" hex head nut driver, secure

the damper assembly with the five (5) provided zinc-plated #10 x 3/8"

screws.

Align notch and dimple.

Figure A-8

Figure A-9

Figure A-10

(continued on next page)

Inner transition collar (rear)

Inner transition (rear)

firebox front

InstallIng thE Est-50 outEr transItIon assEmbly

(continued from previous page)

damper assembly:
Inner Transition Collar
Damper Link

Inner transition

flange