Important safety instructions, Save these instructions, Electromagnetic compatibility – Liebert GXT2-6000RTL630 User Manual

Page 5: Warning

Advertising
background image

1

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS

This manual contains important safety instructions. Read all safety, installation and operating

instructions before operating the Uninterruptible Power Supply (UPS). Adhere to all warnings on the

unit and in this manual. Follow all operating and user instructions. Individuals without previous

training can install and operate this equipment.
It is not intended for use with life support and other designated critical devices. Maximum load must

not exceed that shown on the UPS rating label. The UPS is designed for data processing equipment. If

uncertain, consult your local dealer or Liebert representative.
This UPS is designed for use on a properly grounded (earthed), 208, 220, 230 or 240 VAC, 50Hz or

60Hz supply. The factory default setting is 208VAC, 60Hz. Installation instructions and warning

notices are located in this manual.
This UPS is for use only with a three-wire input: L1, L2, G.

Electromagnetic Compatibility

The GXT2-6000RTL630 Series complies with the limits for a CLASS A DIGITAL DEVICE, PURSU-

ANT TO Part 15 of FCC rules. Operation is subject to the following two conditions: (1) This device

may not cause harmful interference and (2) this device must accept any interference received, includ-

ing interference that may cause undesired operation. Operating this device in a residential area is

likely to cause harmful interference that users must correct at their own expense.
Operate the UPS in an indoor environment only in an ambient temperature range of 32°F to 104°F

(0°C to 40°C). Install it in a clean environment, free from conductive contaminants, moisture, flam-

mable liquids, gases and corrosive substances.
This UPS contains no user serviceable parts except the internal battery pack. The Off/Bypass push

button does not electrically isolate internal parts. Under no circumstances attempt to gain access

internally other than to replace the batteries due to risk of electric shock or burn. Do not continue to

use the UPS if the front panel indications are not in accordance with these operating instructions or if

the UPS performance alters in use. Refer all faults to your local dealer, Liebert representative or the

Liebert Worldwide Support Group.
Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and

the required precautions. Keep unauthorized personnel away from the batteries. PROPER DIS-

POSAL OF BATTERIES IS REQUIRED. REFER TO YOUR LOCAL LAWS AND REGULATIONS

FOR BATTERY DISPOSAL REQUIREMENTS.
Never block or insert any object into the ventilation holes or other openings of the UPS.
DO NOT CONNECT equipment that could overload the UPS or demand half-wave rectification from

the UPS, for example: electric drills, vacuum cleaners, laser printers, hair dryers or any other appli-

ance using half-wave rectification.
Storing magnetic media on top of the UPS may result in data loss or corruption.
Turn the UPS off and isolate the UPS before cleaning; use only a soft cloth, never liquid or aerosol

cleaners. Keep the front and rear vents free of dust accumulation that could restrict airflow.

!

WARNING

Opening or removing the cover may expose you to lethal voltages within this unit even when

it is apparently not operating and the input wiring is disconnected from the electrical source.
Observe all cautions and warnings in this manual. Failure to do so may result in serious

injury or death. Refer all UPS and battery service to qualified service personnel. Do not

attempt to service this product yourself. Never work alone.