Postscript, Manualfeedtimeout, Newsheet – Lexmark C762 User Manual

Page 207: Pagecount

Advertising
background image

PostScript

4-30

manualfeedtimeout

/manualfeedtimeout

integer

def

is an integer key in

statusdict

that works with the

ManualFeedTimeout

page

device parameter to determine the manualfeed timeout for a given page.

If during a print job,

manualfeedtimeout

is defined as an integer value in

statusdict

, that value is used instead of the

ManualFeedTimeout

page device

parameter.

The value of the

ManualFeedTimeout

page device parameter and

manualfeedtimeout

key in

statusdict

are independent of each other; the value

of one does not affect the value of the other.

0

disabled

1...65355

seconds

An

undefined

error results if

manualfeedtimeout

is queried before the value is

set.

Errors:

stackoverflow, undefined

newsheet

— newsheet —

causes the current page to start on the front side of a new sheet.

Error:

none

pagecount

— pagecount

integer

queries the value of the

PageCount

system parameter. An integer is returned on

the stack indicating the current page count.

This operator is equivalent to executing the following PostScript emulation
sequence:

currentsystemparams /PageCount get

Error:

stackoverflow

Advertising