8-12

Table 8-1 shows all protocol timings in nanoseconds.

Fastbytes Protocol Data Transfer Sequence

Your printer is equipped with

Fastbytes

protocol, which is an enhanced parallel

interface protocol. Fastbytes protocol may give you a faster data transfer time on some
personal computers and operating systems. Fastbytes protocol is the printer default.

If you have data transmission problems between your personal computer and the
printer, change the parallel protocol to

Standard

. This causes the printer to operate in

IEEE-compliant compatibility mode.

The following illustration shows the typical timing sequence.

Table 8-1: Typical Parallel Interface Timings

Time

Name

Minimum/Maximum

A

Data setup to STROBE* low

500 min.

B

STROBE* width

500 min.

C

Data hold after STROBE*

500 min.

D

STROBE* low to BUSY high

500 max.

E

ACKNLG* low until ACKNLG* high

500 min.

F

ACKNLG* high to BUSY low

1

G

BUSY low and ACKNLG* high to STROBE* low

500 min.

1

Relationship of ACKNLG* and BUSY is not consistent