Protocol (rs-232c), Interfaces – Lexmark C762 User Manual

Page 316

Advertising
background image

Interfaces

8-24

Protocol (RS-232C)

Table 8-4 shows the state or function of each serial interface signal in the three data
flow control protocols when the Honor DSR setting is On.

Table 8-5 shows the state of each serial interface signal in the three data flow control
protocols when the Honor DSR setting is Off.

Table 8-4: Serial Link (All Protocols) with Honor DSR On

Printer

XON/XOFF Protocol
(Honor DSR On)

DTR Protocol
(Honor DSR On)

DTR/DSR Protocol
(Honor DSR On)

DTR

Always active

Flow control to computer

Flow control to
computer

DSR

Data validity

Data validity

Flow control (transmit
mode) to computer
(receive mode)

CTS

Ignored

Flow control from computer

Ignored

Table 8-5: Serial Link (All Protocols) with Honor DSR Off

Printer Signal

XON/XOFF Protocol
(Honor DSR Off)

DTR Protocol
(Honor DSR Off)

DTR/DSR Protocol
(Honor DSR Off)

DTR (Output)

Always active

Flow control to
computer

Flow control to computer

DSR (Input)

Ignored

Ignored

1

Flow control to computer

CTS (Input)

Ignored

Flow control from
computer

1

Ignored

1

These values are compatible with Hewlett-Packard Company’s LaserJet printers.