Postscript – Lexmark C762 User Manual

Page 252

Advertising
background image

PostScript

4-75

StopBits

integer

(Read-only)

Supported values are:

1
2

Type

name

(Read-only) Always returns the value of /Communications.

Device Parameters for the Communication Device %LocalTalk%, %LocalTalkA%, %LocalTalkB%, %LocalTalkC%,
%LocalTalkD%

(%LocalTalk_NV% and %LocalTalk_Pending% contain the same parameters)

DelayedOutputClose

boolean

Selects how the printer manages the port at the end of each print job. Supported values are:

True

An end-of-file message is not sent until the current job and all preceding jobs
finish printing.

False

An end-of-file message is sent as soon as a job finishes executing in the
interpreter, whether or not that job has finished printing.

This value is set independently for each port.

Enabled

boolean

(Read-only)

Supported values are:

True
False

Filtering

name

Indicates if the input needs further filtering before the data can be correctly processed.
Supported values are:

InterpreterBased
None

HasNames

boolean

(Read-only) Always returns False.

Interpreter

name (Read-only)

Supported values are:

PostScript
AutoSelect
PCL
PPDS

LocalTalkType

string

The “type” of the AppleTalk network entity name. This parameter also sets the

Type

parameter to the same value. The new value is returned by the

appletalktype

compatibility

operator.

Legal value: Any string of 32 or fewer non-null characters. Default value is LaserWriter.

Note:

Setting this variable does not affect the value for other physical internal print servers.

The

statusdict

string

appletalktype

is correct for the current job port.

NodeID

integer

(Read-only)

On

boolean

Designates if the communication channel is On and able to receive and send data.
Supported values are:

True

Data is sent and processed.

False

Data is lost.

Table 4-11: PostScript Emulation Device Parameters (Continued)