OPERATION

B-12

B-12

CLASSIC II

TABLE B.1

RANGE SETTINGS FOR WIRE SIZE/SPEED

Diameter (inches)

Wire Speed Range

Appropriate Current Range

(inches/minute)

.035

80-110

75 to 120 Amps

.045

70-130

120 to 170 Amps

.068

40-90

125 to 210 Amps

TO USE THE CLASSIC II FOR DC WIRE
FEED WELDING (CONSTANT VOLTAGE)
WITH WIRE FEED MODULE:

1.

Connect the LN-25 or LN-7 Wire Feeder (with wire
feed module). Follow the installation instructions
provided with the wire feeder.

2.

Select the appropriate electrode.

3.

Start the diesel engine. See

Engine Operation in

this section of the manual.

4.

Set the Idler Switch to "AUTO."

5.

Set the CURRENT RANGE SELECTOR to a set-
ting appropriate for your wire size and speed. See
Table B.1 for recommended settings.

6.

Set the VOLTAGE ADJUSTMENT to the setting
that gives the best arc characteristics for the range
selected. See

Control of Welding Current in this

section of the manual.

7.

Strike an arc and begin welding.