CONNECTION OF THE LN-7 TO THE
CLASSIC II USING K584 INPUT CABLE
ASSEMBLY (SEE FIGURE C.2.)

1. Shut the welder off.

2. Connect the electrode cable from the LN-7 to the

“+” terminal of the welder. Connect the work cable
to the “CV-” terminal of the welder.

NOTE: Welding cable must be sized for current and

duty cycle of application.

NOTE: Figure C.2 shows the electrode connected for

positive polarity. To change polarity, shut the
welder off and reverse the electrode and work
cables at the Classic II output terminals .

3. Connect the input cable from the K584-XX Input

Cable Assembly to the 14 pin amphenol on the
K864 adapter and the input cable plug on the LN-
7.

4. Connect the K864 adapter to the 14 pin amphenol

on the Classic II.

5. Place the IDLER switch in the "HIGH" position.

Any increase of the high idle engine RPM by changing
the governor setting or overriding the throttle linkage
will cause an increase in the AC auxiliary voltage. If
this voltage goes over 140 volts, wire feeder control
circuits may be damaged. The engine governor set-
ting is preset at the factory — do not adjust above
RPM specifications listed in this manual.

6. Adjust wire feed speed and voltage at the LN-7.

NOTE:

For remote control, a K857 control is
required. Connect it to the K864 adapter.

When the welder is in local control, the electrode is
always "HOT."

ACCESSORIES

C-5

C-5

CLASSIC II

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

CAUTION

CAUTION

FIGURE C.2

CLASSIC II/LN-7 WITH K584 INPUT CABLE ASSEMBLY CONNECTION DIAGRAM

Classic II Output
Terminals are on
Opposite Side

TO
WORK

ELECTRODE CABLE
TO LN-7

14 PIN
AMPHENOL

14 PIN
AMPHENOL

6 PIN
AMPHENOL

K857
REMOTE CONTROL

K864
ADAPTER

K584-"L" INPUT CABLE

LN-7
CONTROL
BOX

CV-

+

Advertising