TROUBLESHOOTING & REPAIR

F-44

F-44

CLASSIC II

GENERATOR FRAME REMOVAL

AND REPLACEMENT

(continued)

FIGURE F.21 – GENERATOR LEAD AND CABLE CONNECTIONS

SELECTOR

SWITCH
CABLES

BLUE AND

BROWN LEADS

PROCEDURE

1. Turn the engine OFF.

2. Perform the

Alternator Rotor Removal

procedure.

3. Perform the

Alternator Stator Removal

procedure.

4. Cut all necessary cable ties.

5. Disconnect the blue and the brown wires at

the in-line connectors. See Figure F. 21 and
the Wiring Diagram.

6. With the 3/4" wrench, remove the cable from

the positive output terminal.

7. Label the five cables that are connected to the

selector switch. Otherwise, you will need to
see the Wiring Diagram during reassembly.

8. With the 1/2" wrench, remove the five cables

connected to the selector switch.

9. Carefully clear all remaining leads and set the

front panel assembly to the left side of the
machine. On later models, remove leads #62
and #58 from the circuit breaker located on
the output terminal assembly.