ELECTRIC SHOCK can kill.

• Do not operate with panels open.

• Disconnect NEGATIVE (-) BATTERY

LEAD before servicing.

• Do not touch electrically live parts.

MOVING PARTS can injure.

• Keep guards in place.

• Keep away from moving parts.

• Only qualified personnel should install,

use or service this equipment.

CONNECTION OF THE LN-7 TO THE
CLASSIC II USING K867 UNIVERSAL
ADAPTER (SEE FIGURE C.1.)

1.

Shut the welder off.

2.

Connect the electrode cable from the LN-7 to the
“+” terminal of the welder. Connect the work
cable to the “CV–” terminal of the welder.

NOTE: Welding cable must be sized for current

and duty cycle of application.

NOTE: Figure C.1 shows the electrode connected

for positive polarity. To change polarity,
shut the welder off and reverse the elec-
trode and work cables at the Classic II
output terminals.

3. Connect the K867 Universal Adapter to the K291 or

K404 input cable and the 14 pin amphenol of the
Classic II as indicated in Figure C.1. Make the
proper connections for local or remote control
according to Figure C.1.

4. Connect the K291 or K404 input cable to the LN-7.

5. Place the IDLER switch in the “HIGH” position.

Any increase of the high idle engine RPM by changing
the governor setting or overriding the throttle linkage
will cause an increase in the AC auxiliary voltage. If
this voltage goes over 140 volts, wire feeder control
circuits may be damaged. The engine governor set-
ting is preset at the factory — do not adjust above
RPM specifications listed in this manual.

6. Adjust wire feed speed and voltage at the LN-7.

NOTE: For remote control, a K775 remote control is

required. See Figure C.1.

When the welder is in local control, the electrode is
always “HOT.”

ACCESSORIES

C-4

C-4

CLASSIC II

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

CONNECTION OF LINCOLN ELECTRIC WIRE FEEDERS

WARNING

CAUTION

CAUTION

FIGURE C.1

CLASSIC II/LN-7 WITH K867 ADAPTER CONNECTION DIAGRAM

Classic II Output
Terminals are on
Opposite Side

Splice Leads
and Insulate

Insulate Each
Unused Lead
Individually

TO
WORK

14 PIN
AMPHENOL

LN-7
CONTROL
BOX

SPARE

82
81
42
41

31

31

32

32

2

2

4

4

21

75
76
77

75
76
77

21

GND

GND

GREEN

K291 OR K404
INPUT CABLE

K775 OPTIONAL
REMOTE CONTROL

K867 UNIVERSAL
ADAPTER PLUG

ELECTRODE CABLE
TO LN-7

CV-

+