I/O Commands 143

Set IOChannel

Set IOChannel Digital Output (Serial Pins)

output

Specify how the channel output will be handled:

z

Manual—You must manually manipulate the channel output.

z

Pulse—Activates and deactivates the channel output activity in intervals after it is
manually activated.

z

Inactive-to-Active Delay—The channel output will remain inactive for the
specified time interval after it is manually started.

z

Active-to-Inactive Delay—The channel output will go inactive after the specified
time interval after it is manually started.

The default is

Manual

.

pulse

When the

Output

is

Pulse

, you can have it pulse in a

Continuous

manner or specify a

pulse

Count

(each count consists of an active/inactive sequence). The default is

Continuous

.

active-to-inactive-delay

When the I/O is commanded to an inactive state, this is the length of the delay before
the command is executed. Valid values are 1-9999 x 100 ms. The default is 100 ms.

inactive-to-active-delay

When the I/O is commanded to an active state, this is the length of the delay before the
command is executed. Valid values are 1-9999 x 100 ms. The default is 100 ms.

Description Sets the Digital output for serial pins RTS and DTR. This option is only available when

the

Line Service

is set to

Signal I/O

.

User Level Admin
Syntax

set iochannel rts|dtr [description <string>]

[failsafe-action none|activate-outut|deactivate-output]

[mode enabled|disabled]

Options

description

Provide a description of the channel, making it easier to identify. The channel
description can be up to 20 characters.

failsafe-action

When there has been no I/O activity within the specified time (set in the Global
Settings) and the

Failsafe Timer

is triggered, you can set the

Failsafe Action

to:

z

None—The state of the Digital/Relay output remains the same, no change.

z

Activate Output—Activates the channel.

z

Deactivate Output—Deactivates the channel.

mode

Enables the channel, allowing the settings to become active.