Line Commands 93

Line Service Commands

Set Power-Management Line

slave-ip

The IP address of the TCP/Ethernet Modbus Slave.

uid-range

When

Range Mode

is

Host

and you have sequential Modbus Slave IP addresses (for

example, 10.10.10.1, 10.10.10.2, 10.10.10.3, etc.), you can specify a UID range and the
IOLAN will automatically increment the last digit of the configured IP address.
Therefore, you can specify a UID range of 1-100, and the IOLAN will route Master
Modbus messages to all Modbus Slaves with IP addresses of 10.10.10.1 - 10.10.10.100.

Description Configures the power management settings for the line.
User Level Admin
Syntax

set power-management line .|<number>|*

[model rps820|rps830|rps1620|rps1630] [name <bar_name>]

set power-management line .|<number>|* plug <1-8|1-16>

[default-state on|off] [name <plug_name>]

[power-up-interval .5|1|2|5|15|30|60|120|180|300]

[serial-line <number>]

Options

model

Specify the power bar model, either RPS820, RPS830, RPS1620, RPS1630.

name (power bar name)

Specify a name for the RPS.

plug

Specify the power bar plug number you are configuring.

default-state

Sets the default state of the plug, either

on

or

off

. The default is

off

.

name (plug name)

Specify a name for the plug to make it easier to recognize and manage.

power-up-interval

Specify the amount of time, in seconds, that the power bar will wait before powering up
a plug. This can be useful if you have peripherials that need to be started in a specific
order.

serial-line

Associate a serial line(s) connected to a serial device that is plugged into the power bar
on that plug.