A. Configuration Options

8700-A2-GB20-40

May 2002

A-7

DSX-1 Interface Options (Model 8777)

For the Model 8777’s DSX-1 Interface Options, refer to

Table A-4, DSX-1 Interface

Options – Model 8777

. To access the DSX-1 Interface Options screen, follow this

menu selection sequence:

Main Menu

Configuration

Current Configuration

DSX-1

Table A-4.

DSX-1 Interface Options – Model 8777 (1 of 2)

Port Status

Possible Settings: Enable, Disable
Default Setting: Enable

Determines whether the port can be configured and used.

Enable – The port can be configured and used.

Disable – The port cannot be configured or used. Configuration fields for the port are
inaccessible, no alarms or traps associated with the port are generated, and the LED
associated with the port is OFF.

NOTE: Cross-connections are not cleared when a port is disabled.

Line Coding Format

Possible Settings: AMI, B8ZS
Default Setting: B8ZS

Specifies the line coding format to be used by the DSX-1 interface.

AMI – Indicates the line coding format used by the DSX-1 interface is Alternate Mark
Inversion (AMI).

B8ZS – Indicates the line coding format used by the DSX-1 interface is B8ZS.

main/config/DSX-1

Slot: 18 Model: 8777

Port 2

DSX-1 INTERFACE OPTIONS

Port Status: Enable

Line Coding B8BS

Line Framing: ESF

Line Equalization: 0 -133

Excessive Error Rate Threshold: 1E-4

Primary Clock Source: DSX-1

--------------------------------------------------------------------------------