Self-Test Results Messages

The results of the last power-on or reset self-test appear in the middle column of
the System and Test Status screen.

Table 7-2.

Self-Test Results Messages (1 of 2)

Message

What Message Indicates

What To Do

CPU Fail

The Central Processing Unit
failed internal testing.

1. Reset the unit and try again.

2. Call your service

representative for
assistance.

CPU CPLD Fail

The Complex Programmable
Logic Device serving the
Central Processing Unit
failed.

Data Path Fail, Pt

n

The port shown failed to loop
data on the full data path test.

DeviceFailed

One or more of the unit’s
integrated circuits has failed
device-level testing.

DSL
Framer

x

Fail

Th e DSL framer for Ports
1– 4 (Framer A) or
5 – 8 (Framer B) failed.

DSL xcvr Fail, Pt

n

The DSL transceiver failed
on Port

n

.

DSX-1 Failed, Pt

n

The unit failed to internally
loop data on the DSX-1
Port

n

.

DTE
Framer

x

Fail

The DTE framer for Ports
1– 4 (Framer A) or
5 – 8 (Framer B) failed.

DTE LIU

x

Fail

The DTE Line Interface Unit
for Ports 1– 2 (LIU A),
3 – 4 (LIU B), 5 – 6 (LIU C), or
7 – 8 (LIU D) failed.

EEPROM Fail

The unit failed Electrically
Erasable Programmable
Read-Only Memory
verification.

Failure

xxxxxxxx

An internal failure occurred.

(xxxxxxxx

represents an

8-digit hexadecimal failure
code for use by service
personnel.)

Record the failure code
and contact your service
representative.

Advertising