A. Configuration Options

8700-A2-GB20-40

May 2002

A-41

7. Set Inband Management Select to Enable, and enter the port (1) and time slot

(1) to support Inband Management. Save your changes.

8. Use the Assign Time Slots screen to verify that Inband Management has been

assigned to Port 1 TS 1. Follow this menu selection sequence:

Main Menu

Configuration

Current Configuration

Cross-Connect

Assign Time Slots

The following screen appears:

Procedure

To test the inband management configuration:

1. Connect the G.703 port to the MUX/DCAS to be used in the test.

2. Configure the upstream router for PPP mode. The router’s WAN port should

be configured on the same IP address segment as the MCP card.

main/config/cross_connect/timeslot

Slot: 18 Model: 8779

ASSIGN TIME SLOTS

G.703 Port: 1 DSOs to Allocate: Start TS: Assign To: D

TS01 TS02 TS03 TS04 TS05 TS06 TS07

I D D D D D D

TS08 TS09 TS10 TS11 TS12 TS13 TS14

D D D D D D D

TS15 TS16 TS17 TS18 TS19 TS20 TS21

D D D D D D D

TS22 TS23 TS24 TS25 TS26 TS27 TS28

D D D D D D D

TS29 TS30 TS31

D D D

Key: D = DSL, G = G.703 I = IBMC

d = data, v = voice

--------------------------------------------------------------------------------

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit

Save Clear_All