Assigning time slots, A-24 – Paradyne U8777 User Manual

Page 120

Advertising
background image

A. Configuration Options

A-24

May 2002

8700-A2-GB20-40

Assigning Time Slots

For Assign Time Slots configuration options, refer to

Table A-11, Assign Time Slots

Options

. To access the Assign Time Slots screen, select Assign_DS0s on the

Cross-Connect Mode screen, or follow this menu selection sequence:

Main Menu

Configuration

Current Configuration

Cross-Connect

Assign Time Slots

The following screen is displayed for a DSX-1 port (Model 8777):

The following screen is displayed for a G.703 port (Model 8779):

main/config/cross_connect/timeslot

Slot: 18 Model: 8777

ASSIGN TIME SLOTS

DSX-1 Port: 1 DSOs to Allocate: Start TS: Assign To: D

TS01 TS02 TS03 TS04 TS05 TS06 TS07

D d D d D d D d D d D d D d

TS08 TS09 TS10 TS11 TS12 TS13 TS14

D d D d D d D d D d D d D d

TS15 TS16 TS17 TS18 TS19 TS20 TS21

D d D d D d D d D d D d D d

TS22 TS23 TS24

D d D d D d

Key: D = DSL, X = DSX-1

d = data, v = voice

--------------------------------------------------------------------------------

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit

Save Clear_All

main/config/cross_connect/timeslot

Slot: 18 Model: 8779

ASSIGN TIME SLOTS

G.703 Port: 1 DSOs to Allocate: Start TS: Assign To: D

TS01 TS02 TS03 TS04 TS05 TS06 TS07

D d D d D d D d D d D d D d

TS08 TS09 TS10 TS11 TS12 TS13 TS14

D d D d D d D d D d D d D d

TS15 TS16 TS17 TS18 TS19 TS20 TS21

D d D d D d D d D d D d D d

TS22 TS23 TS24 TS25 TS26 TS27 TS28

D d D d D d D d D d D d D d

TS29 TS30 TS31

D d D d D d

Key: D = DSL, G = G.703 I = IBMC

d = data, v = voice

--------------------------------------------------------------------------------

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit

Save Clear_All

Advertising