Paradyne U8777 User Manual

Page 75

Advertising
background image

7. Monitoring and Troubleshooting

8700-A2-GB20-40

May 2002

7-23

Table 7-5

shows the meaning of the possible values for each LED represented.

Table 7-5.

Display LEDs Screen

Type

Label

Value is . . .

Indicating . . .

SYSTEM

Alarm

On

Off

Device failure, Power-On Self-Test (POST)
failure, ports inoperable or unable to train.

No alarms.

Test

On

Off

Loopback test or 511 test pattern in progress.

No tests.

DSX-1
PORT

P1
through
P8

Link Up

Link Down

LOF

EER

Yellow

AIS

Disabled

Recoverable signal present on the DSX-1
network.

No signal on the port.

The port has a Loss of Frame alignment.

The port has an Excessive Error Rate
condition.

The port received a Yellow Alarm.

The port received an Alarm Indication Signal.

The port has been administratively disabled.

G.703
PORT

P1
through
P8

Link Up

Link Down

LOF

EER

RAI

AIS

Disabled

Recoverable signal present on the G.703
network.

No signal on the port.

The port has a Loss of Frame alignment.

The port has an Excessive Error Rate
condition.

The port received a Remote Alarm Indication.

The port received an Alarm Indication Signal.

The port has been administratively disabled.

DSL LOOP

P1
through
P8

Link Up

Link Down

Startup

OOF

Disabled

DSL link is up.

DSL link is down.

DSL training in progress.

Out Of Frame condition.

The port has been administratively disabled.

Advertising
This manual is related to the following products: