Inband management channel options – model 8779, Table a-16 – Paradyne U8777 User Manual

Page 134

Advertising
background image

A. Configuration Options

A-38

May 2002

8700-A2-GB20-40

Table A-16. Inband Management Channel Options – Model 8779

Inband Management Select

Possible Settings: Enable, Disable
Default Setting: Disable

Specifies whether data on the selected port and time slot will be sent according to the
cross-connect configuration or to the MCC card instead.

Enable – Enables the Inband Management Channel.

Disable – Disables the Inband Management Channel.

Inband Management Type

Possible Setting: PPP, Frame Relay
Default Setting: PPP

Specifies the type of data the Inband Management Channel will accept.

PPP – The Inband Managment Channel will accept Point-to-Point Protocol (PPP) data.

Frame Relay

The Inband Management Channel will accept Frame Relay data.

Inband Management Port

Possible Settings: 1 8
Default Setting: 1

Selects the G.703 port for the Inband Management Channel. Only ports configured for
DS0 cross-connection or Unassigned are eligible for inband management.

Inband Management Time Slot

Possible Settings: 1 15 or 17 31
Default Setting: 1

Selects the G.703 time slot for the Inband Management Channel.

Inband Management DLCI

Possible Settings: 16 1007
Default Setting: 16

Selects the Data Link Connection Identifier (DLCI) the Inband Management Channel will
use when Inband Management Type is set to Frame Relay.

Inband Management LMI

Possible Settings: Annex A, Annex D, Standard
Default Setting: Standard

Selects the Local Management Interface (LMI) the Inband Management Channel will use
when Inband Management Type is set to Frame Relay.

Annex A

The LMI supported is specified by Q933 Annex A.

Annex D

The LMI supported is specified by ANSI T1.617 Annex D.

Standard

The standard LMI is supported.