IntelliTouch ScreenLogic User’s Guide

Configuring Valve Actuators

To assign a valve actuator:

1. Start the ScreenLogic Configurator and tap Configure IntelliTouch.

2. Tap Next on the General Setting page and on the Setup Circuits page. The Configure Other Equipment

(Step 3 of 5) page is displayed.

3. Select the Load Center or Expansion Center(s) and the AUX valve actuator (A, B) you wish to configure

from the Valve Assignments list.

Note: When using solar heat, note that for shared equipment pool and spa combination, valve A is
always used for solar. For dual body dual equipment, valve A is always the pool and valve B is
always the spa.

Valve A: Can be used for solar heating or auxiliary valve actuator control. If the “Solar present” check box is
selected “USED BY SOLAR” is displayed in the Valve assignment list. Valve A is automatically configured as
a solar heating valve actuator.

Valve B: Can be configured to be controlled by any circuit. Resides on the Personality board.

Valves C D E: Reside on the optional Valve Module board (P/N 520285) that is plugged into the Personality
board.

4. In the Circuit Assigned to Valve box, select the circuit that you would like to use to control the valve

actuator.

5. Repeat steps 3 and 4 for each valve actuator.

6. Tap Finish when done.