119

Run 20-30 prints. The
impression will disappear
with continued time and
use.

A single color shows a
light, repeating
horizontal line.

The roller in the toner
cartridge has a slight
impression after a long
period of storage.

Care and Maintenance

The photosensitive belt
inside the imaging unit is
scratched.

Replace the imaging unit.

The imaging unit has
reached its useful life.

Corrective Action

Straight, thin light
vertical line in colors.

Trouble

Prints are missing fine-
line detail.

Replace the imaging unit.

Possible Cause

The imaging unit has
reached its useful life.

Dark color spots and
dark or light streaks
appear in all colors.

Replace the imaging unit.

Replace the imaging unit.

The imaging unit’s
internal waste toner box
is full.

Each color “bleeds” into
the color band.