Channels

Digital I/O Extension

Overview

The Digital I/O extension feature connects a digital input signal to digital output(s)/relay(s) and/or a
TCP/IP application over an IP network. Therefore, when the state of the digital input changes, you
can also change the state of the digital output or relay channel or output serial signal pin on a local
I/O channel(s), other IOLAN I/O channels, other IOLAN serial signal pins, or the data can be sent to
an application(s).

For example, when the door opens (I/O digital input sensor) in a factory, a light goes on in the
reception office (remote IOLAN relay channel), and the door open/close is logged by an application
on a remote host.

Active Signal
Width

How long the channel will be active during the pulse mode.

Range: 1-9999 x 100 ms

Default: 1 (100 ms)

Delay

How long to delay an active-to-inactive or inactive-to-active setting after it is
manually started.

Range: 1-9999 x 100 ms

Default: 1 (100 ms)

Failsafe Action

When there has been no I/O activity within the specified time (set in the I/O
Interfaces
, Settings on the Failsafe Timer tab) and the

Failsafe Timer

is

triggered.

Data Options:

z

None—The state of the Digital/Relay output remains the same, no change.

z

Activate Output—Activates the channel.

z

Deactivate Output—Deactivates the channel.

Default: None